Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Assunto principal
Intervalo de ano de publicação
1.
Heliyon ; 10(4): e26429, 2024 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-38434061

RESUMO

The presence of missing data is a significant data quality issue that negatively impacts the accuracy and reliability of data analysis. This issue is especially relevant in the context of accelerated tests, particularly for step-stress accelerated degradation tests. While missing data can occur due to objective factors or human error, high missing rate is an inevitable pattern of missing data that will occur during the conversion process of accelerated test data. This type of missing data manifests as a degradation dataset with unequal measuring intervals. Therefore, developing a more appropriate imputation method for accelerated test data is essential. In this study, we propose a novel hybrid imputation method that combines the LSSVM and RBF models to address missing data problems. A comparison is conducted between the proposed model and various traditional and machine learning imputation methods using simulation data, to justify the advantages of the proposed model over the existing methods. Finally, the proposed model is implemented on real degradation datasets of the super-luminescent diode (SLD) to validate its performance and effectiveness in dealing with missing data in step-stress accelerated degradation test. Additionally, due to the generalizability of the proposed method, it is expected to be applicable in other scenarios with high missing data rates.

2.
Zhongguo Yi Liao Qi Xie Za Zhi ; 48(1): 75-79, 2024 Jan 30.
Artigo em Chinês | MEDLINE | ID: mdl-38384221

RESUMO

The gradual acceleration of the aging population in China has led to an increased demand for mobility aids, and the reliability of domestic wheeled walking-aid is one of their important attributes, but there is little research on the reliability of mobility aids. This paper conducts the failure mode, effects and criticality analysis on domestic wheeled walking-aid. By collecting, collating and analyzing the 26 failure modes, the key modules are the chassis and the lifting system. The key modules are obtained, and the failure data is analyzed to find out that the lifetime distribution model is log-normal and the 0.95 lower confidence limit for reliability life of product t 0.9 is 2489.4 hours. The study aims to provide ideas for the reliability analysis of other active medical devices and calls for the formation of a reliability study review point for the industry that meets the requirements of Chinese medical device regulations.


Assuntos
Caminhada , Reprodutibilidade dos Testes , China
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA